Summative evaluation and human factors validation assess whether intended users can operate a medical device safely when performing safety-critical tasks. The evaluation is conducted using the final user interface under representative conditions of use.
We plan, organise and document summative evaluations in accordance with IEC 62366-1 and human factors validation tests aligned with FDA requirements. This helps manufacturers assess safety-related usability and prepare regulatory evidence for the European and US markets.
The evaluation takes place once the safety-related design of the medical device has been finalised. It is particularly relevant before market launch or following changes to existing products that require reassessment.
Typical questions include:
The evaluation provides a traceable basis for assessing safety-related usability and preparing documentation in accordance with the EU Medical Device Regulation (MDR) or FDA requirements.
Together with the manufacturer, we define relevant user groups, hazard-related use scenarios and evaluation criteria. The findings of the use-related risk analysis provide the foundation.
For the US market, we also consider specific FDA expectations, particularly regarding critical tasks, representative user groups and test conditions.
We develop an evaluation plan, define realistic tasks and prepare the test environment. Participants are selected to represent the intended user groups and meet the relevant regulatory expectations.
We consider appropriate participant numbers, relevant use scenarios and realistic simulations of the intended conditions of use.
We conduct the evaluation using the final user interface. We observe and document the performance of safety-critical tasks, including use errors, difficulties and close calls.
Testing takes place under representative conditions. We investigate whether users can perform the relevant tasks safely and identify the underlying causes of any errors.
We analyse observations, investigate the causes of use errors and document the results. The findings contribute to the final assessment of safety-related usability.
Depending on the target market, we prepare a summative evaluation report in accordance with IEC 62366-1 or a Human Factors Validation Report aligned with FDA expectations.
You receive structured, traceable documentation of the summative evaluation or human factors validation to support your regulatory submission or technical documentation.
Depending on the project scope, deliverables include:
This provides a robust foundation for assessing the safety-related usability of your medical device and supports regulatory submissions for the European and US markets.